Schistosoma latex agglutination test

In the immunological diagnosis of schistosomiasis, almost all kinds of immunological tests have been tried. In addition, there are cercaria membrane test and ring egg sedimentation test using Schistosoma cercariae and eggs as antigens. The schistosomiasis latex agglutination test is now introduced. Basic Information Specialist classification: Infectious disease inspection and classification: pathogenic microorganism inspection Applicable gender: whether men and women apply fasting: not fasting Analysis results: Below normal: Normal value: no Above normal: negative: normal. Positive: The sensitivity of this method is 89.5%~93.8%, the false positive rate is 0%~3%, and there is a 7.7%-10% cross reaction with filariasis, clonorchiasis and paragonimiasis, but the intensity is obviously low. In the same kind of reaction. Tips: Indirect hemagglutination test with schistosomiasis. But the operation is simple, fast, but slightly less sensitive. Normal value negative. Clinical significance The sensitivity of this method is 89.5%~93.8%, the false positive rate is 0%~3%, and there is a 7.7%-10% cross reaction with filariasis, clonorchiasis and paragonimiasis, but the intensity is obviously low. In the same kind of reaction. The antibody negative condition after treatment was similar to the indirect hemagglutination method. The antigen used in this method is stable, easy to operate and fast, and is suitable for on-site application in general clinical laboratories and epidemic areas. Positive results may be diseases: schistosomiasis, vaginal schistosomiasis, schistosomiasis, pulmonary schistosomiasis, cerebral schistosomiasis Indirect hemagglutination test with schistosomiasis. But the operation is simple, fast, but slightly less sensitive. Inspection process Molecular biological diagnostics use polymerase chain reaction to detect its immunogenicity. Not suitable for the crowd Those who do not have an indication for examination should not do this check. Adverse reactions and risks 1, subcutaneous hemorrhage: due to pressing time less than 5 minutes or blood draw technology is not enough, etc. can cause subcutaneous bleeding. 2, discomfort: the puncture site may appear pain, swelling, tenderness, subcutaneous ecchymosis visible to the naked eye.

Was this article helpful?

The material in this site is intended to be of general informational use and is not intended to constitute medical advice, probable diagnosis, or recommended treatments.